Main content

Caterpillar

C1.5 Generator Set

Minimum Rating

10.0 kVA

10.0 kVA

Maximum Rating

13.5 kVA

13.5 kVA

Emissions/Fuel Strategy

R96/EUIIIa Equivalent

R96/EUIIIa Equivalent

Features

Details

Specifications

Spec Value
Minimum Rating 10.0 kVA 10.0 kVA
Maximum Rating 13.5 kVA 13.5 kVA
Emissions/Fuel Strategy R96/EUIIIa Equivalent R96/EUIIIa Equivalent
Voltage 110 to 415 Volts 110 to 415 Volts
Frequency 50 Hz 50 Hz
Speed 1500 rpm 1500 rpm
Duty Cycle Standby, Prime Standby, Prime
Spec Value
Engine Model Cat® C1.5 Cat® C1.5
Bore 3.3 in 84 mm
Stroke 3.5 in 90 mm
Displacement 91.3 in³ 1.5 l
Compression Ratio 22.5:1 22.5:1
Aspiration Naturally Aspirated Naturally Aspirated
Fuel System Indirect Injection Indirect Injection
Governor Type Mechanical Mechanical
Spec Value
Length – Maximum 55.1 in 1400 mm
Width – Maximum 24.4 in 620 mm
Height – Maximum 41.5 in 1054 mm

Standard Equipment

Air Inlet System

  • Air cleaner; light duty with disposable element
  • Air cleaner; light duty with disposable element

Control Panel

  • EMCP 4.1
  • EMCP4.1 control panel

Cooling System

  • Caterpillar extended life coolant
  • Radiator and cooling fan with guards
  • Coolant drain line with valve
  • Fan drive, battery charging alternator drive
  • Radiator and cooling fan with guards

Exhaust System

  • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
  • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose

Fuel System

  • Standard open set fuel tank / base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank
  • Standard open set fuel tank / base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank

Generators and Generator Attachments

  • Segregated low voltage (AC/DC) wiring panel
  • IP23 Protection
  • Voltage regulator (single phase sensing)
  • 12 leads
  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • Tower panel, IP22, bottom cable entry
  • 12 leads
  • Tower panel, IP22, bottom cable entry
  • Segregated low voltage (AC/DC) wiring panel
  • IP23 Protection

Governing System

  • Mechanical governing system
  • Mechancial governing system

Lube System

  • Oil drain line with valve
  • Lubricating oil
  • Lubricating oil
  • Oil drain line with valve

Mounting System

  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provisions and termination points for coolant
  • includes lifting provisions and termination points for coolant
  • Captive linear vibration isolators between base and engine-generator

Starting / Charging System

  • 12 Volt battery with rack and cables
  • 12V battery with rack and cables

General

  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

Alternator Options

  • Coastal insulation protection

Certificates

  • Global certification for CIS
  • European upgrade to STD set for CE certificate

Circuit Breakers

  • 4 Pole circuit breaker
  • Pad-locable breaker device

Control Panel Options

  • EMCP 4.2
  • Battery charger
  • Emergency stop with key
  • Volt free contacts for genset running
  • Volt free contacts for common alarm

Cooling System

  • Coolant heater

Enclosures

  • Single point lift for enclosure
  • Sound attenuated enclosure (GALV)

Fuel System

  • Low fuel level alarm

Mounting Options

  • Industrial silencer removal
  • Battery removal
  • Silencer installation kit

Special Test and Inspection

  • PGS test report @ 1.0 power factor

General

  • Packing case – canopied set
  • Packing Case – compact set
  • Radiator Stone Guard

Sign up for Riggs Cat Emails