Cat Generator Set Package
Main content
Cat
C7.1 ACERT
Maximum Rating
220 kVA
220 kVA
Minimum Rating
135 kVA
135 kVA
Emissions/Fuel Strategy
Non Regulated, EU Stage IIIA
Non Regulated, EU Stage IIIA
Overview
Producing reliable power from 135 to 220 kVA at 50 Hz, our C7.1 diesel generator sets designed to ISO 8528-5 transient response requirements. All C7.1 generator sets are available with a choice of emissions levels.
Media
Photos
360° View
Exterior
Enclosure Spin Set
Documents
- Electric Power Ratings Guide
- DE150E0 50 Hz 150.0 kVA, 60 Hz, 165.0 ekW, LC-Frame, Low BSFC Compliant Spec Sheet
- DE165E0 50 Hz 165.0 kVA, 60 Hz, 187.5 ekW, LC-Frame, Low BSFC Compliant Spec Sheet
- DE165E3 50 Hz 165.0 kVA, LC-Frame, EU IIIA Compliant Spec Sheet
- DE175E3 50 Hz 175.0 kVA, LC-Frame, EU IIIA Compliant Spec Sheet
- DE200E0 50 Hz 200.0 kVA, 60 Hz, 218.8 ekW, LC-Frame, Low BSFC Compliant Spec Sheet
- DE200E3 50 Hz 200.0 kVA, LC-Frame, EU IIIA Compliant Spec Sheet
- DE220E0 50 Hz 220.0 kVA, LC-Frame, Low BSFC Compliant Spec Sheet
- DE150E0 50 Hz 150.0 kVA, M-Frame, Low BSFC Compliant Spec Sheet
- DE165E0 50 Hz 165.0 kVA, M-Frame, Low BSFC Compliant Spec Sheet
- DE165E3 50 Hz 165.0 kVA, M-Frame, EU IIIA Compliant Spec Sheet
- DE200E0 50 Hz 200.0 kVA, M-Frame, Low BSFC Compliant Spec Sheet
- DE200E0 50 Hz 200.0 kVA, M-Frame, Low BSFC Compliant Spec Sheet
- DE200E3 50 Hz 200.0 kVA, M-Frame, EU IIIA Compliant Spec Sheet
- DE220E0 50 Hz 200.0 kVA, M-Frame, Low BSFC Compliant Spec Sheet
- DE165E0 50 Hz 165.0 kVA, 60 Hz 187.5 kVA, R-Frame, Low BSFC Compliant Spec Sheet
- DE165E0 50 Hz 165.0 kVA, 60 Hz 187.5 kVA, R-Frame, Low BSFC Compliant Spec Sheet
- DE200E0 50 Hz 200.0 kVA, 60 Hz 218.8 kVA, R-Frame, Low BSFC Compliant Spec Sheet
- DE165E3 50 Hz 165.0 kVA, R-Frame, EU IIIA Compliant Spec Sheet
- DE220E0 50 Hz 220.0 kVA, R-Frame, Low BSFC Compliant Spec Sheet
Details
Specifications
Generator Set Specifications
Spec | Value |
---|---|
Maximum Rating | 220 kVA 220 kVA |
Minimum Rating | 135 kVA 135 kVA |
Emissions/Fuel Strategy | Non Regulated, EU Stage IIIA Non Regulated, EU Stage IIIA |
Voltage | 110 to 480 Volts 110 to 480 Volts |
Frequency | 50 Hz 50 Hz |
Speed | 1500 rpm 1500 rpm |
Duty Cycle | Standby, Prime Standby, Prime |
Engine Specifications
Spec | Value |
---|---|
Engine Model | Cat® C7.1 Cat® C7.1 |
Bore | 4.1 in 105 mm |
Stroke | 5.3 in 135 mm |
Displacement | 427.8 in³ 7 l |
Compression Ratio | 16.0:1, 18.2:1 16.0:1, 18.2:1 |
Aspiration | Turbocharged, Air to Air Aftercooled Turbocharged, Air to Air Aftercooled |
Fuel System | Direct Injection Direct Injection |
Governor Type | Mechanical Mechanical |
Generator Set Dimensions
Spec | Value |
---|---|
Length – Maximum | 98.4 in 2500 mm |
Width – Maximum | 52 in 1320 mm |
Height – Maximum | 64 in 1626 mm |
Standard Equipment
Air Inlet System
- Air cleaner; light duty with disposable element
Control Panels
- EMCP 4.1
Cooling System
- Radiator and cooling fan with guards
- Fan drive, battery charging alternator drive
- Coolant drain line with valves
- Caterpillar extended life coolant
Fuel System
- Base, formed steel with single wall integral 8-hour fuel tank
- Standard open set fuel tank/base supplied
Exhaust System
- Stub pipe, gaskets, raincap and SAE exhaust flange for customer use – shipped loose
Generator and Generator Attachments
- Segregated low voltage (AC/DC) wiring panel
- Voltage regulator (single phase sensing)
- Tower panel, IP22, bottom cable entry
- 12 Leads
Governing System
- Mechanical and electrical governing system – model dependent
Lube System
- Oil drain line with valve
- Lubricating oil
Generators and Generator Attachments
- IP23 Protection
- Circuit breaker, IEC, 3 pole, mounted in tower panel
Mounting System
- Includes lifting provision and drag points
- Captive linear vibration isolators between base and engine-generator
- Captive linear vibration isolators between base and engine-generator
- Termination points for coolant and lube oil drain lines
Starting / Charging System
- 24V battery with rack and cables
General
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
Alternator System
- 3 Phase sensing
- Optional LC Frame alternator
- Optional LC Frame alternator with coastal insulation protection
- R Frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
- Permanent magnet excitation (PMG)
- Quatrature droop king
- Alternator removal
- Anti-condensation heater
Circuit breakers
- 4 Pole 250A, 400A and 630A Circuit breakers
- Padlockable breaker device
Control System
- 1000001235
- Static battery charger
- Control panel heater
- Volt free contacts for common alarm
- Volt free contacts for generator set running
Control Panel Options
- Overload shutdown via breaker
Cooling System
- Low coolant level shutdown
- Coolant heater
- Low coolant temperature
Enclosures
- Rental options (CAE only) – Single point lift
- Rental options (CAE only) – Rental pack
- Rental options (CAE only) – CEE form sockets for enclosure
- Sound attenuated level 2 enclosure
- Sound attenuated level 1 enclosure
- Rental options (CAE only) – Socket blanking plate
European Certifications
- Upgrade to STD set for CE
Fuel Systems
- Skidbase for CALG enclosure sets
- Open set narrow tankbase
- Low fuel level alarm
- DEFRA bunded fuel tank
- Low fuel level shutdown
- High fuel level alarm
- Compact skidbase for open sets
Global Certifications
- Certification for CIS
Mounting Options
- Electronic governor
- Industrial silencer removal
- Residential silencer
- Battery removal
- Silencer installation kit
Test Reports
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8 power factor
General
- Stone guards/radiator trans flange
Power Termination
- Circuit breaker, IEC, 4 pole
Accessories / Miscellaneous
- Packing case – compact set
- Packing case – canopied set