Cat Generator Set Package
Main content
Cat
C1.5 Generator Set
Maximum Rating
13.2 ekW
13.2 ekW
Minimum Rating
12.0 ekW
12.0 ekW
Emissions/Fuel Strategy
R96/EUIIIa Equivalent
R96/EUIIIa Equivalent
Overview
Producing reliable power from 12 to 13.2 ekW at 60 Hz, our C1.5 diesel generator sets designed to ISO 8528-5 transient response requirements. All C1.5 generator sets are R96/EUIIIa equivalent emissions compliant.
Media
Photos
360° View
Exterior
360° interior view. Double click on the image to zoom in on any area of the product.
Documents
- Electric Power Ratings Guide
- DE11E3S 50 Hz 11.0 kVA, 60 Hz 13.0 kVA, M Frame, EU IIIA Compliant Emissions Spec Sheet
- DE13.5E3 50 Hz 13,5 kVA, 60 Hz 16.5 kVA, M Frame, EU IIIA Compliant Emissions Spec Sheet
- DE11E3S 50 Hz 11.0 kVA, 60 Hz 13.0 kVA, LC Frame, EU IIIA Compliant Emissions Spec Sheet
- DE13.5E3 50 Hz 13.5 kVA, 60 Hz 16.5 kVA, LC Frame, EU IIIA Emissions Compliant Spec Sheet
- C1C2 Diesel Generator Set, 6.8 – 22 kVA, 50/60 Hz Spec Sheet
- C1C2 Diesel Generator Set, 6.8 – 22 kVA, 50/60 Hz Spec Sheet
Details
Specifications
Generator Set Specifications
Spec | Value |
---|---|
Maximum Rating | 13.2 ekW 13.2 ekW |
Minimum Rating | 12.0 ekW 12.0 ekW |
Emissions/Fuel Strategy | R96/EUIIIa Equivalent R96/EUIIIa Equivalent |
Voltage | 110 to 415 Volts 110 to 415 Volts |
Frequency | 60 Hz 60 Hz |
Speed | 1800 rpm 1800 rpm |
Duty Cycle | Standby, Prime Standby, Prime |
Engine Specifications
Spec | Value |
---|---|
Engine Model | Cat® C1.5 Cat® C1.5 |
Bore | 3.3 in 84 mm |
Stroke | 3.5 in 90 mm |
Displacement | 91.3 in³ 1.5 l |
Compression Ratio | 22.5:1 22.5:1 |
Aspiration | Naturally Aspirated Naturally Aspirated |
Fuel System | Indirect Injection Indirect Injection |
Governor Type | Mechanical Mechanical |
Generator Set Dimensions
Spec | Value |
---|---|
Length – Maximum | 55.1 in 1400 mm |
Width – Maximum | 24.4 in 90 mm |
Height – Maximum | 41.5 in 1054 mm |
Standard Equipment
Air Inlet System
- Air cleaner; light duty with disposable element
Control Panel
- GCCP 1.3
Cooling System
- Radiator and cooling fan with guards
- Coolant drain line with valve
- Fan drive, battery charging alternator drive
- Caterpillar extended life coolant
Exhaust System
- Stub pipe, gaskets, raincap & SAE exhaust flange for customer use – shipped loose
Fuel System
- Base, formed steel with single wall integral 8-hour fuel tank
- Standard open set fuel tank/base supplied
Generators and Generator Attachments
- Voltage regulator (single phase sensing)
- IP23 Protection
- Segregated low voltage (AC/DC) wiring panel
- Tower panel, IP22, bottom cable entry
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- 12 Leads
Governing System
- Mechanical governing system
Lube System
- Oil drain line with valve
- Lubricating oil
Mounting System
- Captive linear vibration isolators between base and engine-generator
- includes lifting provisions and termination points for coolant
Starting / Charging System
- 12 Volt battery with rack and cables
General
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
Alternator Options
- Coastal insulation protection
Certificates
- Global certification for CIS
- European upgrade to STD set for CE certificate
Circuit breakers
- Padlockable breaker device
- 4 Pole Circuit breaker
Control Panel Options
- Emergency stop with key
- Volt free contacts for genset running
- Battery charger
- Volt free contacts for common alarm
- GCCP 1.3
Cooling System
- Coolant heater
Enclosures
- Sound attenuated enclosure (GALV)
- Single point lift for enclosure
Fuel System
- Low fuel level alarm
- DEFRA bunded fuel tank
- 1000 Hr extended service interval
- Fuel transfer control
- Skidbase for open sets
- Base feet
- Skidbase for enclosures
Mounting Options
- Silencer installation kit
- Industrial silencer removal
- Battery removal
Special Test and Inspection
- PGS Test report @ 1.0 power factor
General
- Packing case – canopied set
- Packing Case – compact set
- Radiator stone guard