Main content

Caterpillar

C1.1 Generator Set

Minimum Rating

8.0 ekW

8.0 ekW

Maximum Rating

8.8 ekW

8.8 ekW

Emissions/Fuel Strategy

R96/EUIIIa Equivalent

R96/EUIIIa Equivalent

Features

Details

Specifications

Spec Value
Minimum Rating 8.0 ekW 8.0 ekW
Maximum Rating 8.8 ekW 8.8 ekW
Emissions/Fuel Strategy R96/EUIIIa Equivalent R96/EUIIIa Equivalent
Voltage 110 to 480 Volts 110 to 480 Volts
Frequency 60 Hz 60 Hz
Speed 1800 rpm 1800 rpm
Duty Cycle Standby, Prime Standby, Prime
Spec Value
Engine Model C1.1, In-line 4, 4-cycle diesel C1.1, In-line 4, 4-cycle diesel
Bore 3 in 77 mm
Stroke 3.2 in 81 mm
Displacement 69 in³ 1.1 l
Compression Ratio 23.0:1 23.0:1
Aspiration Naturally Aspirated Naturally Aspirated
Fuel System Indirect Injection Indirect Injection
Governor Type Mechanical Mechanical
Spec Value
Length – Maximum 55.1 in 1400 mm
Width – Maximum 24.4 in 620 mm
Height – Maximum 39.2 in 996 mm

Standard Equipment

Air Inlet System

  • Air cleaner; light duty with disposable element
  • Air cleaner; light duty with disposable element

Control Panel

  • EMCP 4.1
  • EMCP4.1 control panel

Cooling System

  • Fan drive, battery charging alternator drive
  • Radiator and cooling fan with guards
  • Caterpillar extended life coolant
  • Coolant drain line with valve
  • Radiator and cooling fan with guards

Exhaust System

  • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
  • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose

Fuel System

  • Base, formed steel with single wall integral 8-hour fuel tank
  • Standard open set fuel tank / base supplied
  • Standard open set fuel tank / base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank

Generators and Generator Attachments

  • Segregated low voltage (AC/DC) wiring panel
  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • 12 Leads
  • Voltage regulator (single phase sensing)
  • Tower panel, IP22, bottom cable entry
  • IP23 Protection
  • Base, formed steel with single wall integral 8-hour fuel tank
  • Tower panel, IP22, bottom cable entry
  • IP23 Protection
  • 12 leads

Governing System

  • Mechanical governing system
  • Mechancial governing system

Lube System

  • Lubricating oil
  • Oil drain line with valve
  • Lubricating oil
  • Oil drain line with valve

Mounting System

  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provisions and termination points for coolant
  • Captive linear vibration isolators between base and engine-generator
  • includes lifting provisions and termination points for coolant

Starting / Charging System

  • 12 Volt battery with rack and cables
  • 12V battery with rack & cables

General

  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

Alternator Options

  • Coastal insulation protection

Certificates

  • Global certification for CIS
  • European upgrade to STD set for CE certificate

Circuit Breakers

  • Pad-lockable breaker device
  • 4 Pole circuit breaker

Control Panel

  • Battery charger
  • Volt free contacts for common alarm
  • EMCP 4.2
  • Volt free contacts for genset running
  • Emergency stop with key

Cooling System

  • Coolant heater

Enclosures

  • Sound attenuated enclosure (GALV)
  • Single point lift for enclosure

Fuel System

  • Skidbase for open sets
  • Fuel transfer control
  • DEFRA bunded fuel tank
  • 1000 hr extended service interval
  • Base feet
  • Skidbase for Enclosures
  • Low fuel level alarm

Mounting Options

  • Silencer installation kit
  • Industrial silencer removal
  • Battery removal

Special Test and Inspection

  • PGS test report @1.0 power factor

General

  • Packing case – canopied set
  • Radiator stone guard
  • Packing case – compact set

Sign up for Riggs Cat Emails

  • This field is for validation purposes and should be left unchanged.