Main content
Cat
3606 Generator Set (Medium Speed)
Maximum Rating
2000 ekW
2000 ekW
Minimum Rating
1650 ekW
1650 ekW
Emissions/Fuel Strategy
Low Fuel Consumption
Low Fuel Consumption
Overview
Producing reliable power from 1650 to 2000 ekW at 60 Hz, our 3606 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We’ve designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. The generator set is certified for low fuel consumption.
Media
Photos
Details
Specifications
Generator Set Specifications
Spec | Value |
---|---|
Maximum Rating | 2000 ekW 2000 ekW |
Minimum Rating | 1650 ekW 1650 ekW |
Emissions/Fuel Strategy | Low Fuel Consumption Low Fuel Consumption |
Frequency | 60 Hz 60 Hz |
Speed | 900 rpm 900 rpm |
Duty Cycle | Standby, Prime, Continuous Standby, Prime, Continuous |
Engine Specifications
Spec | Value |
---|---|
Engine Model | 3606 I-6,4-Stroke Water-Cooled Diesel 3606 I-6,4-Stroke Water-Cooled Diesel |
Bore | 11 in 280 mm |
Stroke | 11.8 in 300 mm |
Displacement | 111 in³ 6762 l |
Compression Ratio | 13:01 13:01 |
Aspiration | TA TA |
Fuel System | Direct unit injection Direct unit injection |
Governor Type | Generator Set Monitoring System (GMS) Generator Set Monitoring System (GMS) |
Generator Set Dimensions
Spec | Value |
---|---|
Length – Maximum | 404 in 10261.7 mm |
Width – Maximum | 99.62 in 2530.3 mm |
Height – Maximum | 156.6 in 3977.7 mm |
Dry Weight – Genset (maximum) | 74970 lb 34070 kg |
Standard Equipment
Air Inlet System
- Breather, crankcase, top-mounted
- Aftercooler, fresh water, corrosion resistant coated (air side)
- Turbocharger, watercooled (720 rpm and HFO), engine oil lubricated
- Air inlet shutoff
Cooling System
- Jacket water thermostats
- Engine coolant water drains
- Water temperature regulator
Exhaust System
- 457 mm (18 in) Cat bolt pattern
- Includes adapter, flexible exhaust fitting
- Dry, gas tight, exhaust manifold
Fuel System
- Simplex or duplex
Generator System
- Custom generator per generator data sheet completed by dealer
Governor System
- UG Actuator
Lube System
- Centrifugal oil filters with single shutoff
- Oil pressure regulating valve
- Service side engine mounted on cylinder block inspection covers
- Oil filler and dipstick
- Crankcase explosion relief valves
- Wet oil sump. Includes engine-driven main lubrication and oil pumps, oil lines and oil pan
Mounting System
- Damper, torsional vibration
- Engine and generator mounting
Starting / Charging System
- Vane type air starter
- One motor, engine mounted at rear, on left side
- Air silencer
- Line group for single point custom connection
General:
- Paint, Caterpillar yellow
- Gear driven pumps: Fuel/oil/jacket water/aftercooler/Oil cooler water
Optional Equipment
Air Inlet System
- Air inlet adapter
- Air cleaner
- Vertical support bracket
- Heavy duty air cleaner
- Boost control valve
- Air cleaner louver assembly
- Soot filter
Cooling System
- Heating aids
- Cooling system aids
- Expansion tank
- Auxiliary water pump
Exhaust System
- Weld flange and related hardware
- Flexible exhaust fittings
Fuel System
- Duplex primary fuel strainer
- Fuel priming pump
- Fuel system connections
Generator System
- Class F insulation
- 3 Phase, six Leads, WYE
- Busbar connections
- Anti-condensation space heaters
- Winding temperature detectors
Governor System
- EGB actuator
- 723 Plus
- Electronic/actuators
- Battery backup/power supply
- Digital programmers
- 2301 A load share
Lube System
- Oil pan drain valve
- Lube ANSI adapter (Emergency connection)
Mounting System
- Vertically restrained
- Isolator
- Spring type vibration isolators
- Non-vertically restrained
Starting / Charging System
- Compressed air flex hose
- Pressure reducing valve
General:
- Custom paint colors