Cat Generator Set Package
Main content
Cat
C9 Generator Set
Maximum Rating
300 ekW
300 ekW
Minimum Rating
180 ekW
180 ekW
Emissions/Fuel Strategy
EU Stage IIIA, Low Fuel
EU Stage IIIA, Low Fuel
Overview
Producing reliable power from 180 to 300 ekW at 60 Hz, our C9 diesel generator sets designed to ISO 8528-5 transient response requirements. All C9 generator sets are engineered to EPA Stationary Emergency (Tier 3) emissions standards with low fuel consumption.
Media
Photos
360° View
Exterior
Enclosure
Documents
- Electric Power Ratings Guide
- DE200SE0 60 Hz 250 kVA, Non Certified Emissions Spec Sheet
- DE250E0 60 Hz 313 kVA, Non Certified Emissions Spec Sheet
- DE275SE0 60 Hz 344 kVA, Non Certified Emissions Spec Sheet
- DE300SE0 60 Hz 375 kVA, Non Certified Emissions Spec Sheet
- DE300SE3 60 Hz 375 kVA, EU Stage III Emissions Compliant Spec Sheet
- 200 – 300 ekW Spec Sheet
Details
Specifications
Generator Set Specifications
Spec | Value |
---|---|
Maximum Rating | 300 ekW 300 ekW |
Minimum Rating | 180 ekW 180 ekW |
Emissions/Fuel Strategy | EU Stage IIIA, Low Fuel EU Stage IIIA, Low Fuel |
Voltage | 220 to 480 Volts 220 to 480 Volts |
Frequency | 60 Hz 60 Hz |
Speed | 1800 rpm 1800 rpm |
Duty Cycle | Standby, Prime Standby, Prime |
Engine Specifications
Spec | Value |
---|---|
Engine Model | C9 ATAAC, I-6, 4-Stroke Water-Cooled Diesel C9 ATAAC, I-6, 4-Stroke Water-Cooled Diesel |
Bore | 4.41 in 112 mm |
Stroke | 5.87 in 149 mm |
Displacement | 537.01 in³ 8.8 l |
Compression Ratio | 16.1:1 16.1:1 |
Aspiration | Air to Air Aftercooled Air to Air Aftercooled |
Fuel System | Hydraulic electronic unit injection Hydraulic electronic unit injection |
Governor Type | Adem™A4 Adem™A4 |
Generator Set Dimensions
Spec | Value |
---|---|
Length – Maximum | 157 in 3988 mm |
Width – Maximum | 47.5 in 1207 mm |
Height – Maximum | 73.5 in 1867 mm |
Standard Equipment
Air Inlet System
- Air cleaner, light duty with disposable paper filter
- Turbocharger
- Air cleaner, light duty with disposable paper filter
Control Panels
- GCCP 1.3
- EMCP4.4 control panel
Cooling System
- Radiator and cooling fan with guard
- Fan drive, battery charging alternator drive
- Coolant drain line with valve
- Caterpillar extended life coolant
- Radiator and cooling fan with guard
Exhaust System
- Stainless steel exhaust flex, gaskets, rain cap & SAE exhaust flange for customer use – shipped loose
- Flange for customer; shipped loose
- Stainless steel exhaust flex, gaskets, rain cap and SAE exhaust
Fuel System
- Standard open set fuel tank/base supplied
- Base, formed steel with single wall integral 8-hour fuel tank
- Standard open set fuel tank/base supplied
- Base, formed steel with single wall integral 8-hour fuel tank
Generators and Generator Attachments
- Mandatory option circuit breaker, IEC, 3 pole mounted in power centre
- Power centre, IP22
- Voltage regulator (single phase sensing)
- 12 Leads
- IP23 Protection
- Segregated low voltage (AC/DC) wiring panel
- IP23 Protection
- 12 Leads
Governing System
- Cat electronic governor (ADEM A4)
- Cat electronic governor (ADEM A4)
Lube System
- Oil cooler
- Lubricating oil
- Oil drain valves
Mounting System
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provisions and termination points for coolant and lube oil drain lines
Starting / Charging System
- 24V battery with rack and cables
General
- Engine and alternator re-paint, Caterpillar yellow
- Engine and alternator re-paint, Caterpillar yellow
Optional Equipment
Certifications
- European Certificate for Conformance
- Global Certification for CIS
Air inlet system
- Single element air cleaner
Circuit breakers
- 4 Pole (IEC-100% rated) Circuit breaker upgrades: 400, 630, 800 and 100 amps
Control Panels
- Oil temperature displays
- Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; overload shutdown via breaker ; Low fuel level shutdown ; Low fuel level alarm ; Fuel level sensor
Cooling System
- Radiator duct flange
- Low coolant temperature alarm
Enclosures
- Sound attenuated enclosure
- High ambient sound attenuated enclosure
Exhaust System
- Mufflers – End in/end out; 10 dBA or 25 dBA attenuation
- 5 and 6 inch elbow kits
- 6 inch flange
- 5 – 6 inch flange adaptor
Fuel System
- Integral dual wall fuel tank base
Generators and Attachments
- Permanent magnet excitation (PMG) generator
- Oversize, AREP, CIP generators
Mounting System
- Narrow skid base
Starting / Charging System
- Battery disconnet switch
- Jacket water heater
- 5 Amp single Battery charger