Cat Generator Set Package
Main content
Cat
DE150 GC Generator Set (60 Hz)
Maximum Rating
132 ekW
132 ekW
Minimum Rating
132 ekW
132 ekW
Emissions/Fuel Strategy
Non Regulated
Non Regulated
Overview
Producing reliable power of 132 ekW at 60 Hz, our DE150 GC diesel generator set is designed to meet ISO 8528-5 transient response requirements.
Media
Photos
360° View
Exterior
Details
Specifications
Generator Set Specifications
Spec | Value |
---|---|
Maximum Rating | 132 ekW 132 ekW |
Minimum Rating | 132 ekW 132 ekW |
Emissions/Fuel Strategy | Non Regulated Non Regulated |
Voltage | 220 to 480 Volts 220 to 480 Volts |
Frequency | 60 Hz 60 Hz |
Speed | 1800 rpm 1800 rpm |
Duty Cycle | Standby Standby |
Engine Specifications
Spec | Value |
---|---|
Engine Model | C7.1 I-6, 4-Cycle Diesel C7.1 I-6, 4-Cycle Diesel |
Bore | 4.1 in 105 mm |
Stroke | 5.3 in 135 mm |
Displacement | 427.8 in³ 7 l |
Compression Ratio | 18.2:1 18.2:1 |
Aspiration | Turbocharged Turbocharged |
Fuel System | Inline Inline |
Governor Type | Mechanical Mechanical |
Generator Set Dimensions
Spec | Value |
---|---|
Length – Maximum | 130.9 in 3325 mm |
Width – Maximum | 44.6 in 1134 mm |
Height – Maximum | 65.6 in 1666 mm |
Dry Weight – Genset (maximum) | 4043 lb 1834 kg |
Standard Equipment
Engine
- C7.1, Inline 6 cylinder, 4 stroke diesel
Control Panels
- GCCP 1.1
Fuel Storage
- Single wall 8 hour fuel tank
Governor
- Mechanical governor
Enclosure
- Cat GC enclosure
Alternator
- A Frame standard alternator
Air, Cooling & Exhaust
- Enclosure silencer
General
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
Auxiliary Supply Voltage
- 120V
Certification
- Certificate of Conformance
- Australia, CIS, Gulf Certification
Alternator Requirements
- Space heater
Fuel Storage
- Dual wall 8 hour fuel tank
- Low fuel level alarm
- High fuel level alarm
- Low fuel level shutdown
- Single wall tank with containment
Circuit breaker
- 3 Pole Circuit breaker 630A
- 4 Pole Circuit breaker 250A
- 4 Pole Circuit breaker 200A
- 3 Pole Circuit breaker 250A
- 3 Pole Circuit breaker 200A
- 4 Pole Circuit breaker 400A
- 4 Pole Circuit breaker 630A
- Circuit breaker padlock
- Neutral earth link
- Overload via alarm switch on breaker
- 3 Pole Circuit breaker 400A
Genset Control
- Panel mounted audible alarm
- Battery charger
- Earth leakage
- Volt free contacts for genset running
- Volt free contacts for common alarm
- Earth fault
- Emergency stop with key
- USB to RS485 Communications device
- Coolant heater
- Battery
- Low coolant level shutdown
- Standby Pack (Smart Jacket water heater, Battery charger)
Testing & Packaging
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8PF