Main content

Cat

DE150 GC Generator Set (60 Hz)

Maximum Rating

132 ekW

132 ekW

Minimum Rating

132 ekW

132 ekW

Emissions/Fuel Strategy

Non Regulated

Non Regulated

Overview

Producing reliable power of 132 ekW at 60 Hz, our DE150 GC diesel generator set is designed to meet ISO 8528-5 transient response requirements.

Media

Photos

360° View

Exterior

Features

Details

Specifications

Spec Value
Maximum Rating 132 ekW 132 ekW
Minimum Rating 132 ekW 132 ekW
Emissions/Fuel Strategy Non Regulated Non Regulated
Voltage 220 to 480 Volts 220 to 480 Volts
Frequency 60 Hz 60 Hz
Speed 1800 rpm 1800 rpm
Duty Cycle Standby Standby
Spec Value
Engine Model C7.1 I-6, 4-Cycle Diesel C7.1 I-6, 4-Cycle Diesel
Bore 4.1 in 105 mm
Stroke 5.3 in 135 mm
Displacement 427.8 in³ 7 l
Compression Ratio 18.2:1 18.2:1
Aspiration Turbocharged Turbocharged
Fuel System Inline Inline
Governor Type Mechanical Mechanical
Spec Value
Length – Maximum 130.9 in 3325 mm
Width – Maximum 44.6 in 1134 mm
Height – Maximum 65.6 in 1666 mm
Dry Weight – Genset (maximum) 4043 lb 1834 kg

Standard Equipment

Engine

  • C7.1, Inline 6 cylinder, 4 stroke diesel

Control Panels

  • GCCP 1.1

Fuel Storage

  • Single wall 8 hour fuel tank

Governor

  • Mechanical governor

Enclosure

  • Cat GC enclosure

Alternator

  • A Frame standard alternator

Air, Cooling & Exhaust

  • Enclosure silencer

General

  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

Auxiliary Supply Voltage

  • 120V

Certification

  • Certificate of Conformance
  • Australia, CIS, Gulf Certification

Alternator Requirements

  • Space heater

Fuel Storage

  • Dual wall 8 hour fuel tank
  • Low fuel level alarm
  • High fuel level alarm
  • Low fuel level shutdown
  • Single wall tank with containment

Circuit breaker

  • 3 Pole Circuit breaker 630A
  • 4 Pole Circuit breaker 250A
  • 4 Pole Circuit breaker 200A
  • 3 Pole Circuit breaker 250A
  • 3 Pole Circuit breaker 200A
  • 4 Pole Circuit breaker 400A
  • 4 Pole Circuit breaker 630A
  • Circuit breaker padlock
  • Neutral earth link
  • Overload via alarm switch on breaker
  • 3 Pole Circuit breaker 400A

Genset Control

  • Panel mounted audible alarm
  • Battery charger
  • Earth leakage
  • Volt free contacts for genset running
  • Volt free contacts for common alarm
  • Earth fault
  • Emergency stop with key
  • USB to RS485 Communications device
  • Coolant heater
  • Battery
  • Low coolant level shutdown
  • Standby Pack (Smart Jacket water heater, Battery charger)

Testing & Packaging

  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8PF

Sign up for Riggs Cat Emails