Cat Generator Set Package
Main content
Cat
DE110E2 (50 Hz) Generator Set
Minimum Rating
110.0 kVA
110.0 kVA
Maximum Rating
110.0 kVA
110.0 kVA
Emissions/Fuel Strategy
EU Stage II R96
EU Stage II R96
Overview
Producing reliable power 110.0 kVA at 50 Hz, our DE110E2 generator set powerd by C4.4 diesel engine designed to ISO 8528-5 transient response requirements.
DE110E2 generator sets is EUIIa equivalent emissions compliant.
Media
Photos
360° View
Exterior
Enclosure
Documents
- Electric Power Ratings Guide
- DE110E2, 50 Hz 110.0 kVA, LC Frame, EUII Emissions Compliant Spec Sheet
- DE110E2, 50 Hz 110.0 kVA, M Frame, EUII Emissions Compliant Spec Sheet
- DE110E2, 50 Hz 110.0 kVA, R Frame, EUII Emissions Compliant Spec Sheet
- Sound Attenuated Level 1 Enclosures 30 – 220 kVA (50 and 60 Hz)
- Sound Attenuated Level 2 Enclosures 24 – 220 kVA (50 and 60 Hz)
Details
Specifications
Generator Set Specifications
Spec | Value |
---|---|
Minimum Rating | 110.0 kVA 110.0 kVA |
Maximum Rating | 110.0 kVA 110.0 kVA |
Emissions/Fuel Strategy | EU Stage II R96 EU Stage II R96 |
Voltage | 220 to 415 Volts 220 to 415 Volts |
Frequency | 50 Hz 50 Hz |
Speed | 1500 rpm 1500 rpm |
Duty Cycle | Standby, Prime Standby, Prime |
Engine Specifications
Spec | Value |
---|---|
Engine Model | Cat® C4.4 Cat® C4.4 |
Bore | 4.1 in 105 mm |
Stroke | 5 in 127 mm |
Displacement | 201.4 in³ 3.3 l |
Compression Ratio | 18.3:1 18.3:1 |
Aspiration | Turbocharged Turbocharged |
Fuel System | Inline Inline |
Governor Type | Electronic Electronic |
Generator Set Dimensions
Spec | Value |
---|---|
Length – Maximum | 82.2 in 2089 mm |
Width – Maximum | 44.1 in 1120 mm |
Height – Maximum | 54.1 in 1375 mm |
Dry Weight – Genset (maximum) | 2490 lb 1129 kg |
Standard Equipment
Control panel
- GCCP Control panel
Alternator and Alternator attachments
- 12 Leads
- IP23 Protection
- Voltage regulator (single phase sensing)
- Tower panel, IP22, bottom cable entry
- Segregated low voltage (AC/DC) wiring panel
- Circuit breaker, IEC, 3 Pole, mounted in tower panel
Governing system
- Electronic governing system
Cooling system
- Radiator and cooling fan with guards
- Coolant drain line with valve
- Fan drive, battery charging alternator drive
- Caterpillar extended life coolant
Air inlet system
- Air cleaner; light duty with disposable element
Exhaust system
- Stub pipe, gaskets, raincap & SAE exhaust flange
- Industrial silencer
Fuel system
- Standard open set fuel tank/base
Lube system
- Lubricating oil
- Oil drain line with valve
Mounting system
- Captive linear vibration isolators
- Lifting provision and drag points
- Termination points for coolant and lube oil drain lines
Starting/charging system
- 12V Battery with rack & cables
General
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
Control panel
- GCCP Control panel
- Earth fault and earth leakage
- Emergency E-Stop with security key
- 4 Pole Circuit breaker
- Voltage and speed adjust potentiometer
Alternator and Alternator Attachments
- LC Frame alternator
- LC/M Frame alternator
- Space heater
- Permanent magnet excitation (PMG)
- Automatic voltage regulator
- Quadrature droop kit
Enclosures
- Level 1 and Level 2 sound attenuated enclosures
- Single point lifting frame
- Rental pack
- SBOX – CEE form sockets
Alarms and Shutdowns
- Common alarm
- Overload shutdown
- Low coolant level shutdown
- Low coolant temperature alarm
- Low fuel level alarm and shutdown
- High fuel level alarm
Engine
- Jacket water heater
- Battery charger
Fuel system
- Bunded base tank sized for a minimum of 12 hours running with 110% spill protection
Exhaust system
- Residential silencer 25 dBA
Certification
- Certificate of Conformance
- EAC Certification
Extended service coverage
- 3, 4, 5 and 10 Years