Cat Generator Set Package
Main content
Cat
3512 Generator Set
Standby Rating
1400/1250 kVA
1400/1250 kVA
Prime Power Rating
1275/1150 kVA
1275/1150 kVA
Emissions/Fuel Strategy
Low Fuel Consumption
Low Fuel Consumption
Overview
Producing reliable power from 1150 to 1400 kVA at 50 Hz, our 3512 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We’ve designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. Generator sets offer a low fuel consumption system.
Media
Photos
360Ā° View
Exterior
360Ā° Exterior view. Double click on the image to zoom in on any area of the product.
Details
Specifications
Generator Set Specifications
Spec | Value |
---|---|
Standby Rating | 1400/1250 kVA 1400/1250 kVA |
Prime Power Rating | 1275/1150 kVA 1275/1150 kVA |
Emissions/Fuel Strategy | Low Fuel Consumption Low Fuel Consumption |
Voltage | 380 to 415 Volts 380 to 415 Volts |
Frequency | 50 Hz 50 Hz |
Speed | 1500 rpm 1500 rpm |
Duty Cycle | Standby, Mission Critical, Prime, Continuous Standby, Mission Critical, Prime, Continuous |
Maximum Rating | 1400 kVA 1400 kVA |
Minimum Rating | 1000 kVA 1000 kVA |
Engine Specifications
Spec | Value |
---|---|
Engine Model | 3512 TA, V-12, 4-Stroke Water-Cooled Diesel 3512 TA, V-12, 4-Stroke Water-Cooled Diesel |
Bore | 6.69 in 170 mm |
Stroke | 7.48 in 190 mm |
Displacement | 3161.03 inĀ³ 51.8 l |
Compression Ratio | 13.5:1 13.5:1 |
Aspiration | TA TA |
Fuel System | Direct Unit Injection Direct Unit Injection |
Governor Type | Woodward Woodward |
Generator Set Dimensions
Spec | Value |
---|---|
Length – Minimum | 202.7 in 5149 mm |
Length – Maximum | 206.6 in 5249 mm |
Width – Maximum | 77.8 in 1975 mm |
Height – Maximum | 93.2 in 2367 mm |
Dry Weight – Genset (minimum) | 22650 lb 10270 kg |
Dry Weight – Genset (maximum) | 23170 lb 10510 kg |
Standard Equipment
Air Inlet System
- Air cleaner; single element canister type with service indicator
Control Panel
- EMCP4.2B controls includes: Emergency stop pushbutton
- RPM
- Engine cool-down timer
- EMCP4.2B controller includes:
- Accessory module data link
- 4 programmable relay outputs (Form A)
- Communications:
- Volts (L-L & L-N)
- Over/under frequency (81 o / u)
- Text alarm/event descriptions
- Auto/start/stop control
- Speed adjust
- kVA (per phase, average & percent)
- Overcurrent (50 / 51)
- Alarm acknowledge
- Environmental sealed front face
- 6 programmable digital inputs
- Oil pressure (psi, kPa or bar)
- Amps (per phase & average)
- Generator phase sequence
- 2 Programmable digital outputs
- Low coolant temperature
- Controls:
- Serial annunciator module data link
- Reverse power (kW) (32)
- Lamp test
- Coolant temperature
- Engine cycle crank
- kVAr-hr (total)
- 2 Programmable relay outputs (Form C)
- Generator mounted – rear facing
- 24 Volt DC operation
- kVAr (per phase, average & percent)
- Warning/shutdown with common LED indication of shutdowns for:
- kW (per phase, average & percent)
- Reverse reactive power (kVAr) (32RV)
- Programmable protective relaying functions:
- Digital indication for:
- High coolant temperature
- Low oil pressure
- Overspeed
- Over/under voltage (27 / 59)
- Customer data link (Modbus RTU)
- DC volts
- Operating hours
- Low coolant level
- kW-hr (total)
- Frequency (Hz)
- Emergency stop
- Power factor (per phase & average)
- Failure to start (overcrank)
- True RMS AC metering, 3-phase, +/-2% accuracy
Cooling System
- JWAC
- Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)
- Radiator fan and fan drive
- Fan and belt guards
- Coolant drain line with valve
- Coolant level sensors (Not included with packages without radiator)
Exhaust System
- Dry exhaust manifold
- Flanged faced outlet(s)
Fuel System
- Fuel cooler; not included with packages without radiator
- Flexible fuel lines – shipped loose
- Fuel priming pump
- Secondary fuel filters
Generators and Attachments
- Generator set packages include: Regulator (CDVR)
- 6 Lead
- Min / max exciter limiter
- LV
- Reactive droop capability
- Random wound
- Exciter diode monitor
- KVAR/PF modes
- NEMA Class H insulation
- 50 Hz models: IEC standard hole pattern
- Caterpillar’s digital voltage regulator (CDVR) includes:
- Note: 1800 Frames are form wound, permanent magnet excitation (PMG), with winding temp detectors
- Busbar connections, top center mounted, top cable entry
- Internal excitation (IE)
- Winding temperature detectors
- Class H temperature rise at 40C ambient (125C prime/150C standby)
- 3 Phase brushless, Salient pole
- 3 Phase voltage sensing
- RFI suppression
Governing System
- Woodward 2301A isochronous governor
Lube System
- Oil drain lines and valve
- Gear type lube oil pump
- Fumes disposal
- Oil filter, filler and dipstick
- Lubricating oil
- Integral lube Oil cooler
Mounting System
- Rubber anti-vibration mounts – shipped loose
- Rails – engine/generator/radiator mounting
Starting / Charging System
- 24 Volt electric starting motor
- Battery and battery rack w/cables
- Battery disconnect switch
General
- Paint – Caterpillar yellow with high gloss black rails & radiator
- SAE standard rotation
- RH service
- Flywheel and Flywheel housing – SAE No. 00
Optional Equipment
Air Inlet System
- Remote air inlet adaptors
- Air inlet protection
- Dual element air cleaners
Circuit breakers
- EMAX Circuit breakers
- Center posts busbars
- EMAX breakers connections
- Breaker harnesses
- 2000, 2500, 3200 and 4000 Amp, 4 pole, IEC rated Circuit breakers
- Controls packaging – Enclosures
- Cable entry options
- 2000, 2500, 3200 and 4000 Amp, 3 pole, IEC rated Circuit breakers
- Optional busbar power connections
- Busbar connections
Control Panel
- Auxiliary boxes
- Customer connection mounting locations
- Ground (Automatically selected)
- Vandle proof panel door
- Customer Interface options
- Mounting group – External box clips
- Remote speed adjust
- Generator temperature monitoring
- Governors
- Annunciator Modules
- Local PC monitoring
Cooling System
- Water level switch gauges
- Heat exchangers
- Optional radiator arrangements
European Certifications
- EU Declaration of Conformity
- Eurasian Conformity (EAC) mark
- European Directive genset, DoI (Declaration of Incorporation)
- European Union Certification
Exhaust System
- Through-wall installation kit
- Muffler mounting kits
- Mufflers
- Flexible fittings
Fuel System
- Primary fuel filter
Generators and Attachments
- 380 / 400 / 415 Volts @ 50 Hz, 3 phase, Form wound, Permanent magnet excitation (PMG), No. of leads = 6, pitch= 0.6667
- 380/400/415volts @ 50 Hz, 3 phase, random wound, Permanent magnet excitation (PMG), No. of leads = 6, pitch= 0.6667
- Generator conversion
- 380/400/415volts @ 50 Hz, 3 phase, random wound, Internal excitation (IE), No. of leads = 6, pitch= 0.6667
- Space heater
Instrumentation
- Pyrometer and thermocouples
Lube System
- Electric prelube pumps
- Oil level reg-1 shallow pan
- Manual prelube sump pumps
Mounting System
- Spring type vibration isolators
- IBC vibration isolators
Protection System
- Explosion relief valves
Special Tests / Reports
- Neutral grounding connection
- IBC seismic Certifications
- Neutral ground-LV
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8 power factor
Starting / Charging Systems
- Ether starting aid
- 24 Volt dual electric starting motor
- 20 Amp Battery charger
- Oversize battery set
- Jacket water heaters
- 10 Amp Battery chargers
General
- Engine barring group