Main content
Caterpillar
Gas Generator CG132B-16
Continuous Rating
800 kW @1.0pf
800 kW @1.0pf
Fuel Type
Natural Gas, Biogas, Hydrogen Blend (up to 25%)
Natural Gas, Biogas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency
43.5% / 42.6%
43.5% / 42.6%
Overview
The Cat CG132B family of gas engines are perfectly tailored to the challenges of the power plant in an age of global value chains.
Media
Photos
Videos
360° View
Exterior
360 Exterior view. Double click on the image to zoom in on any area of the product.
Details
Specifications
Generator Set Specifications
Spec | Value |
---|---|
Continuous Rating | 800 kW @1.0pf 800 kW @1.0pf |
Fuel Type | Natural Gas, Biogas, Hydrogen Blend (up to 25%) Natural Gas, Biogas, Hydrogen Blend (up to 25%) |
Maximum Electrical Efficiency | 43.5% / 42.6% 43.5% / 42.6% |
Maximum Standby Rating | 800 kW 800 kW |
Frequency | 50 / 60 Hz 50 / 60 Hz |
RPM | 1500 / 1800 rpm 1500 / 1800 rpm |
Engine Specifications
Spec | Value |
---|---|
Engine Model | CG132 CG132 |
Displacement | 2135.8 in³ 35 l |
Aspiration | TA TA |
Bore | 5.2 in 132 mm |
Stroke | 6.3 in 160 mm |
Generator Set Dimensions
Spec | Value |
---|---|
Length | 165 in 4200 mm |
Width | 70 in 1780 mm |
Height | 85 in 2150 mm |
Dry Weight – Genset | 17691 lb 8070 kg |
Standard Equipment
Air Inlet
- Turbocharger with a water-cooled bearing case for all cylinder
- One-element single-stage air cleaner with enclosure and sevice indicator
Control Panels
- TPEM (Total Plant & Energy Management System)
Cooling
- Flange connections for JW inlet and outlet
- Jacket water and SCAC thermostats
- Electrical jacket water and aftercooler coolant pump
- flange connections for JW inlet and outlet
- ANSI/DN customer flange connections for JW inlet and outlet
- Cat flanges on SCAC circuit
Exhaust
- Exhaust waste gate for the CG132B-16
- Closed crankcase ventilation system
- PEARL/Low resistence exhaust system
Fuel system
- Electronic fuel metering valve
- Independently controlled cylinder monitoring and ignition system
- Pre-chamber spark plugs
Generator
- grid code generator
- Reactive droop
- closed-coupled generator result in no torque transmission to the base frame
- Busbar connections
- Anti-condensation space heater
- 3-phase sensing and KVAR/PF control
- Winding temperature detectors
Starting/Charging
- 24V starting motors
- Battery disconnect switch
General
- Crankshaft vibration damper and guard
Optional Equipment
Air Inlet
- Air cleaner with precleaner
- Mounting stand
Cooling
- CHP skid
Grid Code Compliance
- 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands