Main content

Caterpillar

Gas Generator CG132B-16

Continuous Rating

800 kW @1.0pf

800 kW @1.0pf

Fuel Type

Natural Gas, Biogas, Hydrogen Blend (up to 25%)

Natural Gas, Biogas, Hydrogen Blend (up to 25%)

Maximum Electrical Efficiency

43.5% / 42.6%

43.5% / 42.6%

Overview

The Cat CG132B family of gas engines are perfectly tailored to the challenges of the power plant in an age of global value chains.

Media

Photos

Videos

360° View

Exterior

360� Exterior view. Double click on the image to zoom in on any area of the product.

Details

Specifications

Spec Value
Continuous Rating 800 kW @1.0pf 800 kW @1.0pf
Fuel Type Natural Gas, Biogas, Hydrogen Blend (up to 25%) Natural Gas, Biogas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency 43.5% / 42.6% 43.5% / 42.6%
Maximum Standby Rating 800 kW 800 kW
Frequency 50 / 60 Hz 50 / 60 Hz
RPM 1500 / 1800 rpm 1500 / 1800 rpm
Spec Value
Engine Model CG132 CG132
Displacement 2135.8 in³ 35 l
Aspiration TA TA
Bore 5.2 in 132 mm
Stroke 6.3 in 160 mm
Spec Value
Length 165 in 4200 mm
Width 70 in 1780 mm
Height 85 in 2150 mm
Dry Weight – Genset 17691 lb 8070 kg

Standard Equipment

Air Inlet

  • Turbocharger with a water-cooled bearing case for all cylinder
  • One-element single-stage air cleaner with enclosure and sevice indicator

Control Panels

  • TPEM (Total Plant & Energy Management System)

Cooling

  • Flange connections for JW inlet and outlet
  • Jacket water and SCAC thermostats
  • Electrical jacket water and aftercooler coolant pump
  • flange connections for JW inlet and outlet
  • ANSI/DN customer flange connections for JW inlet and outlet
  • Cat flanges on SCAC circuit

Exhaust

  • Exhaust waste gate for the CG132B-16
  • Closed crankcase ventilation system
  • PEARL/Low resistence exhaust system

Fuel system

  • Electronic fuel metering valve
  • Independently controlled cylinder monitoring and ignition system
  • Pre-chamber spark plugs

Generator

  • grid code generator
  • Reactive droop
  • closed-coupled generator result in no torque transmission to the base frame
  • Busbar connections
  • Anti-condensation space heater
  • 3-phase sensing and KVAR/PF control
  • Winding temperature detectors

Starting/Charging

  • 24V starting motors
  • Battery disconnect switch

General

  • Crankshaft vibration damper and guard

Optional Equipment

Air Inlet

  • Air cleaner with precleaner
  • Mounting stand

Cooling

  • CHP skid

Grid Code Compliance

  • 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands

Sign up for Riggs Cat Emails

  • This field is for validation purposes and should be left unchanged.