Main content

Caterpillar

DG200-2 (3 phase)

Frequency

60 Hz

60 Hz

Natural Gas Rating

200 eKW

200 eKW

Emissions/Fuel Strategy

U.S. EPA Certified for Non-Emergency Application

U.S. EPA Certified for Non-Emergency Application

Overview

The Cat® spark-ignited generator product line for stationary applications feature permanent magnet excitation, amortisseur winding, skewed stator, voltage adjustment through the EMCP controller, Class H winding insulation and 2/3 pitch incorporated.

Media

Photos

Features

Details

Specifications

Spec Value
Frequency 60 Hz 60 Hz
Natural Gas Rating 200 eKW 200 eKW
Emissions/Fuel Strategy U.S. EPA Certified for Non-Emergency Application U.S. EPA Certified for Non-Emergency Application
Displacement 864.71 in 14.17 l
Fuel Type Natural Gas Natural Gas
Speed 1800 rpm 1800 rpm
Spec Value
Engine Model 14.2 L, Inline 6, 4 Cycle, Spark - Ignited 14.2 L, Inline 6, 4 Cycle, Spark - Ignited
Fuel System Carburetor, Down Draft Carburetor, Down Draft
Aspiration Turbocharged-Aftercooled Turbocharged-Aftercooled
Governor Type Electronic Electronic
Compression Ratio 9.5:1 9.5:1
Bore 5.31 in 134.87 mm
Stroke 6.5 in 165.1 mm
Spec Value
Length 127.95 in 3250 mm
Width 52.93 in 1344.5 mm
Height 67.37 in 1711.2 mm
Weight 5756 lb 2610.9 kg

Standard Equipment

Cooling

  • Closed coolant recovery system
  • Factory-installed radiator
  • 50/50 Ethylene glycol antifreeze
  • Radiator and cooling fan complete with protective guards
  • Standard ambient temperatures up to 50°C (122°F)

Air Inlet

  • Single element air filter

Fuel

  • Primary and secondary fuel shut-off
  • Low fuel pressure switch
  • Fuel pressure test po
  • Natural Gas or LP Vapor
  • NPT connection
  • Dual lock off valves

Exhaust

  • Exhaust outlet with 3” pipe

Generator

  • Permanent magnet excitation
  • Full load capacity alternator
  • Class H insulation material
  • Permanent magnet excitation
  • Integrated Voltage Regulator
  • Matched to the performance and output characteristics of Cat engines
  • Class H insulation material
  • Full load capacity alternator
  • IP23 Protection

Controls

  • EMCP 4.2 Series generator set controller

Mounting

  • Vibration isolaton (puck type)
  • Rubber vibration isolators

Electric Power - Package Serial Number Prefix

  • Battery charging alternator

Electric Starting and/or Prelube

  • Battery cables
  • Solenoid activated starter motor
  • Engine electrical system
  • Solenoid activated starter motor

Governor

  • Electronic governor (non adjustable)

Control Panel

  • EMCP 4.2 Series generator set controller

Starting/Charging

  • Batteries with rack and cables
  • 12 volt starting motor

Optional Equipment

Starting/Charging

  • Jacket water heater
  • Battery heater
  • Charging alternator
  • Battery charger – UL Listed 10 amp

General

  • Enclosures: sound attenuated, weather protective
  • Suitable for Use as Service Equipment (SUSE)
  • Automatic transfer switches (ATS)
  • UL 2200 package
  • CSA Certification

Generator

  • Thermal magnetic or electronic trip MCCBs
  • Anti-condensation heater
  • Shunt trip and auxiliary contact breaker
  • Anti-condensation heater
  • Excitation: [ ] Permanent Magnet Excited (PM)
  • Oversize and premium generators

Sign up for Riggs Cat Emails

  • This field is for validation purposes and should be left unchanged.