Main content

Cat

XGC1900

Rating

1900 ekW (2375 kVA) Continuous

1900 ekW (2375 kVA) Continuous

Frequency

50/60 Hz

50/60 Hz

Voltage

400/480 V

400/480 V

Overview

In addition to improved fuel efficiency, the next generation XGC1900 rental generator provides significant power density advantages. Caterpillar developed new exhaust stacks that reduce spacing requirements for sites requiring multiple units.

Media

Photos

360° View

Exterior

Features

Details

Specifications

Spec Value
Rating 1900 ekW (2375 kVA) Continuous 1900 ekW (2375 kVA) Continuous
Frequency 50/60 Hz 50/60 Hz
Voltage 400/480 V 400/480 V
Spec Value
Engine Cat G3516H Cat G3516H
Fuel Natural Gas Natural Gas
Spec Value
Width – Without Chassis 96 in 2438 mm
Height – Without Chassis 114 in 2896 mm
Length – Without Chassis 480 in 12192 mm
Weight – Without Chassis, With Lube Oil and Coolant 77780 lb 35280 kg

Standard Equipment

Engine

  • G3516H, V16, 4-stroke-cycle, gas engine. Operates on 24.10 to 93.95 MJ/Nm3 (615 to 2386 btu/ft3) dry pipeline natural gas. Turbocharged Separate Circuit Aftercooled

Generator

  • Double bearing SR5 1866 Frame, brushless, form wound, 12-lead design, permanent magnet excited, thouree-phase, with Cat IVR, Class H insulation operating at Class F temperature. Stator and Bearing temperature monitoring and anti-condensation space heaters

Containerized Module

  • 40′ ISO high cube container, 9-high stack CSC certified. Sound attenuated 79 dB(A) @ 7 m (23 ft) Sound attenuated air intake louvers and 2lockable personnel doors with panic release LH and RH engine service doors integrated intocontainer side walls 3” ANSI flange customer fuel connection

Cooling

  • Standard cooling provides 40⁰C (104⁰F) ambient capability with 500mg/Nm3 NOx at 100% Continuous rating before derate, @ 500m

Generator Controls And Protection

  • On Package EMCP 4.3 Control Panel System Offers engine and generator monitoring and protection, voltage regulation with Cat IVRimproves transient response performance. Controls provide auto paralleling AGC-4 controller, load sharing, VFD control, and primary generator protection for greater versatility, package utilization and monitoring.

Modes of Operation

  • Provides for single unit stand-alone operation,island mode paralleling and load sharing withother power modules, and single unit-to-utilitymode paralleling for base load control

Lube Oil Make-Up System

  • Oil pan-mounted oil level regulator and 114 L (30 gal) oil tank Low level annunciation