Rental Ready
Main content
Cat
XGC1900
Rating
1900 ekW (2375 kVA) Continuous
1900 ekW (2375 kVA) Continuous
Frequency
50/60 Hz
50/60 Hz
Voltage
400/480 V
400/480 V
Overview
In addition to improved fuel efficiency, the next generation XGC1900 rental generator provides significant power density advantages. Caterpillar developed new exhaust stacks that reduce spacing requirements for sites requiring multiple units.
Media
Photos
360° View
Exterior
Details
Specifications
Generator Set
Spec | Value |
---|---|
Rating | 1900 ekW (2375 kVA) Continuous 1900 ekW (2375 kVA) Continuous |
Frequency | 50/60 Hz 50/60 Hz |
Voltage | 400/480 V 400/480 V |
Engine
Spec | Value |
---|---|
Engine | Cat G3516H Cat G3516H |
Fuel | Natural Gas Natural Gas |
Dimensions
Spec | Value |
---|---|
Width – Without Chassis | 96 in 2438 mm |
Height – Without Chassis | 114 in 2896 mm |
Length – Without Chassis | 480 in 12192 mm |
Weight – Without Chassis, With Lube Oil and Coolant | 77780 lb 35280 kg |
Standard Equipment
Engine
- G3516H, V16, 4-stroke-cycle, gas engine. Operates on 24.10 to 93.95 MJ/Nm3 (615 to 2386 btu/ft3) dry pipeline natural gas. Turbocharged Separate Circuit Aftercooled
Generator
- Double bearing SR5 1866 Frame, brushless, form wound, 12-lead design, permanent magnet excited, thouree-phase, with Cat IVR, Class H insulation operating at Class F temperature. Stator and Bearing temperature monitoring and anti-condensation space heaters
Containerized Module
- 40′ ISO high cube container, 9-high stack CSC certified. Sound attenuated 79 dB(A) @ 7 m (23 ft) Sound attenuated air intake louvers and 2lockable personnel doors with panic release LH and RH engine service doors integrated intocontainer side walls 3” ANSI flange customer fuel connection
Cooling
- Standard cooling provides 40⁰C (104⁰F) ambient capability with 500mg/Nm3 NOx at 100% Continuous rating before derate, @ 500m
Generator Controls And Protection
- On Package EMCP 4.3 Control Panel System Offers engine and generator monitoring and protection, voltage regulation with Cat IVRimproves transient response performance. Controls provide auto paralleling AGC-4 controller, load sharing, VFD control, and primary generator protection for greater versatility, package utilization and monitoring.
Modes of Operation
- Provides for single unit stand-alone operation,island mode paralleling and load sharing withother power modules, and single unit-to-utilitymode paralleling for base load control
Lube Oil Make-Up System
- Oil pan-mounted oil level regulator and 114 L (30 gal) oil tank Low level annunciation