Generator Set Specifications
Spec | Value |
---|---|
Minimum Rating | 219 ekW 219 ekW |
Maximum Rating | 940 ekW 940 ekW |
Frequency | 60hz 60hz |
Engine Specifications
Spec | Value |
---|---|
Rated Engine Speed | 1800 rpm 1800 rpm |
Configuration | Vee-12, 4-stroke-Cycle-Diesel Vee-12, 4-stroke-Cycle-Diesel |
Aspiration | Turbocharged-aftercooled aspiration Turbocharged-aftercooled aspiration |
Bore | 5.71 in 145 mm |
Stroke | 6.38 in 162 mm |
Displacement | 1959 in³ 32.1 l |
Governor | Electronic (A4 ECM) Electronic (A4 ECM) |
Emissions | U.S. EPA Tier 3 / IMO II emissions certified U.S. EPA Tier 3 / IMO II emissions certified |
Generator | SR5 - Form Wound SR5 - Form Wound |
Refill Capacity | Lube Oil System w/ oil filter change: 146 L (38.5 gal) Lube Oil System w/ oil filter change: 146 L (38.5 gal) |
Cooling | Heat exchanger, keel or radiator cooled Heat exchanger, keel or radiator cooled |
Oil Change Interval | 750 hrs 750 hrs |
Generator Set Dimensions
Spec | Value |
---|---|
Length | 167.2 in/4245 mm (minimum), 226.1 in/5742 mm (maximum) 167.2 in/4245 mm (minimum), 226.1 in/5742 mm (maximum) |
Width | 59.9 in/1521 mm (minimum), 89.8 in/2280 mm (maximum) 59.9 in/1521 mm (minimum), 89.8 in/2280 mm (maximum) |
Height | 70.4 in/1747 mm (minimum), 92.8 in/2356 mm (maximum) 70.4 in/1747 mm (minimum), 92.8 in/2356 mm (maximum) |
Package Dry Weight | 15721 lb/7131 kg (minimum), 21998 lb/9978 kg (maximum) 15721 lb/7131 kg (minimum), 21998 lb/9978 kg (maximum) |
Standard Equipment
AIR INLET SYSTEM
- Separate circuit aftercooled (SCAC)
CONTROL SYSTEM
- 24V control system
COOLING SYSTEM
- Heat exchanger, keel or radiator cooled
- Watercooled exhaust manifold and turbocharger
- Hard seawater lines – no flexible hoses
- Flanges for cooling connections, ANSI or DIN
FUEL SYSTEM
- Duplex fuel filters with hybrid fuel lines
- Fuel transfer and priming pump
GENERATORS AND GENERATOR ATTACHMENTS
- IP23, air cooled, form wound SR5 generator offered in 440, 480 and 690V
LUBE SYSTEM
- Oil fill, simplex filter and dipstick
MOUNTING SYSTEM
- Helical spring/rubber isolated mounting for vibration and structure borne noise reduction
GENERAL
- Right or left hand service sides
- Customer wiring and service tool connector
Optional Equipment
AIR INLET SYSTEM
- Closed crankcase ventilation
ALARM AND PROTECTION
- MGCP II or MGCP IIIB control panel with Cat® alarm and protection system
- IP44 generator protection
EXHAUST SYSTEM
- Muffler
- SOLAS approved spray shielding
CHARGING SYSTEM
- Charging alternator
CONTROL SYSTEM
- EMCP 4.2 control panel
FUEL SYSTEM
- Installed primary fuel filter with water separator and manual or electric priming pump
- Fuel cooler
LUBE SYSTEM
- Duplex oil filters
STARTING SYSTEM
- Starting motors – air, electric or dual