Main content

Caterpillar

Cat C32 Generator Set (IMO III)

Cat C32 Generator Set, IMO III emissions certified (SCR required)

Media

Photos

Features

Details

Specifications

Spec Value
Minimum Rating 219 ekW 219 ekW
Maximum Rating 940 ekW 940 ekW
Frequency 60hz 60hz
Spec Value
Rated Engine Speed 1500 rpm 1500 rpm
Configuration Vee-12, 4-stroke-Cycle-Diesel Vee-12, 4-stroke-Cycle-Diesel
Aspiration Turbocharged-aftercooled aspiration Turbocharged-aftercooled aspiration
Bore 5.71 in 145 mm
Stroke 6.38 in 162 mm
Displacement 1959 in³ 32.1 l
Governor Electronic (A5 ECM) Electronic (A5 ECM)
Emissions IMO III emissions certified (SCR required) IMO III emissions certified (SCR required)
Refill Capacity Lube Oil System w/ oil filter change: 146 L (38.5 gal) Lube Oil System w/ oil filter change: 146 L (38.5 gal)
Oil Change Interval 750 hrs 750 hrs
Cooling Heat exchanger, keel or radiator cooled Heat exchanger, keel or radiator cooled
Generator SR5 - Form Wound SR5 - Form Wound
Spec Value
Length 167.2 in/4245 mm (minimum), 226.1 in/5742 mm (maximum) 167.2 in/4245 mm (minimum), 226.1 in/5742 mm (maximum)
Width 59.9 in/1521 mm (minimum), 89.8 in/2280 mm (maximum) 59.9 in/1521 mm (minimum), 89.8 in/2280 mm (maximum)
Height 70.4 in/1747 mm (minimum), 92.8 in/2356 mm (maximum) 70.4 in/1747 mm (minimum), 92.8 in/2356 mm (maximum)
Package Dry Weight 15721 lb/7131 kg (minimum), 21998 lb/9978 kg (maximum) 15721 lb/7131 kg (minimum), 21998 lb/9978 kg (maximum)

Standard Equipment

AIR INLET SYSTEM

  • Separate circuit aftercooled (SCAC)
  • Closed crankcase fumes disposal

CONTROL SYSTEM

  • 24V control system

COOLING SYSTEM

  • Heat exchanger or Keel Cooling
  • Watercooled exhaust manifold and turbocharger
  • Hard seawater lines – no flexible hoses
  • Flanges for cooling connections, ANSI or DIN

FUEL SYSTEM

  • Primary fuel filter with water separator installed on base frame
  • Duplex fuel filters with hybrid fuel lines

GENERATORS AND GENERATOR ATTACHMENTS

  • IP23, air cooled, form wound SR5 generator offered in 380, 400, 415 and 690 V

LUBE SYSTEM

  • Oil fill, simplex filter and dipstick

MOUNTING SYSTEM

  • Helical spring/rubber isolated mounting for vibration and structure borne noise reduction

GENERAL

  • Right or left hand service sides
  • Customer wiring and service tool connector

Optional Equipment

ALARM AND PROTECTION

  • MGCPIIIB control panel with Cat® Alarm and Protection System
  • IP44 generator protection

EXHAUST SYSTEM

  • Muffler
  • Water-in-fuel and exhaust temperature sensors
  • SOLAS approved spray shielding

CHARGING SYSTEM

  • Charging alternator

FUEL SYSTEM

  • Manual or electric fuel priming pump
  • Fuel cooler

LUBE SYSTEM

  • Duplex oil filters

STARTING SYSTEM

  • Starting motors – air, electric or redundant